Oil heater KS 85 T
Design and scope of delivery
12
11
10
9
8
7
Fig. 23: Device design
1 Housing with com-
bustion chamber,
heat exchanger and
fan
3 Air inlet
5 Oil filter
7 Base
9 Control panel
11 Hot air outlet
Fig. 24: Inside view
1 Fan
3 Oil pump
5 Combustion cham-
ber
30 / 44
1
2
3
4
5
6
2 Handle
4 Oil pump
6 Fuel tank cap
8 Transport wheel
10 Power cord holder
12 Exhaust gas pipe
2 Motor
4 Nozzle holder
Fig. 25: Combustion chamber and nozzle holder
1 Safety temperature
limiter (STL)
3 Photocell (flame
monitoring)
5 Air inlet adjusting
screw
The scope of delivery includes:
– Oil heater with transport wheels
– Handle
– Exhaust gas pipe
– Operating manual

Mode of operation

6
5
4
Fig. 26: Mode of operation
1 Motor
3 Fan
5 Combustion cham-
ber with burner
The fuel is taken by the oil pump from the tank,
compressed to operating pressure and fed to the
nozzle. The nozzle injects the fuel as a mist into the
combustion chamber where it ignites. The resulting
flame and the combustion gases heat the combus-
tion chamber and the heat exchanger.
The fan conveys cold ambient air along the surfaces
of the combustion chamber and the heat exchange.
The air is thereby heated and exits the device on the
2 Ignition electrode
4 Air inlet of combus-
tion chamber
1
2
3
2 Oil pump
4 Tank
6 Exhaust gas pipe