Installing built-in version

Observe the following instructions when installing:
 Install the refrigerator so that the warm air produced can easily flow away
(either upwards or to the front, fig. 3, page 3).
Key to fig. 3, page 3
No.
Explanation
1
Cold intake air
2
Hot waste air
 Leave the device to stand for at least four hours before you connect it
to the power supply so that the refrigerant can flow back into the
compressor.
 Make sure that the refrigerator door is able to open at least 100°. Other-
wise the drawers cannot be used.
➤ Mount the refrigerator to the furniture by two screws through the fittings at
the bottom (fig. 4, page 3).
6.4
Connecting the refrigerator to the power supply
A
NOTICE!
UK only: The refrigerator is supplied with a plug fitted with 3 A
fuse. In case this fuse has to be to changed, a 3 A ASTA
approved (BS 1362) fuse must be used.
➤ Connect the plug of the connection cable into the AC mains.
➤ Insert the battery into the thermometer (see chapter "Replacing the
battery of the thermometer" on page 17).
✓ The display turns on.
For the first two seconds the display will not show temperature values; it
shows "--.-". Then the temperature read from the sensor is shown.