6. Operation
The equipment consists of an assembly with a
pump, which is encased in a shock absorbing
housing. For an optimal working position the
equipment comes with a lance and a non-slip
gun, whose shape and confi guration comply with
the applicable regulations.
6.1 Using for the fi rst time
Once you have completely assembled the pres-
sure cleaner and made all the connections, pro-
ceed as follows:
Open the water inlet. Release the safety device
(a) (Fig. 3) on the spray gun and pull back trigger
lever (b) (Fig. 3) in order to bleed the trapped air
out of the equipment.
Turn on the equipment by switching the On/Off
switch (Fig. 1/2) to "ON".
Now activate the trigger lever (b).
To turn off , release the trigger lever (b). The
equipment will then go into standby. As soon as
you press the trigger lever (b) again, the pressure
cleaner will restart.
To turn off the pressure cleaner completely, set
the On/Off switch (Fig. 1/3) to "OFF".
6.2 Holder for the gun/accessories (Fig. 2)
The gun and accessories can be kept in the provi-
ded holders (12, 18) in order to save space when
not in use.
6.3 Cable holder (Fig. 2)
The power cable can be wound up on the cable
holder (10) in order to save space when not in
use.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_TC_HP_130_SPK9.indb 20
Anl_TC_HP_130_SPK9.indb 20
GB
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the mains power plug before star-
ting any cleaning work.
8.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could
attack the plastic parts of the equipment. En-
sure that no water can seep into the device.
8.2 Maintenance
8.2.1 Testing the water intake fi lter
Periodically check the intake fi lter in order to pre-
vent clogging, which could jeopardize operation
of the pump.
To do this, unscrew the water inlet connector (9)
from the device and clean the exposed inlet sieve
under running water.
8.2.2 Long periods of nonuse (electric pump)
The machine should be fully emptied of water
each time after use. This requires you to switch on
the equipment without a connected water supply
and to press the trigger lever (b) (max. 1 min.) un-
til no more water emerges. Then you must switch
off the equipment.
If the device is not used for an extended period
of time, lime deposits will begin to form in the
electric pump, which in turn can lead to starting
diffi culties.
8.2.3 Cleaning the nozzle (Fig. 8)
Use the supplied wire (11) to clean clogged nozz-
les.
- 20 -