*Alternative versions of the flue collar exist due to
National requirements. For the flue connection to the
chimney, follow the recommendations from the chimney
manufacturer.
Assembling Front Heat Shield FIG 7
1. Assemble front cover by bending its sides as shown
on the drawing.
2. Place the radiation shield cover on its place as,
take care that slots at the end of cover matches to
hooks of rear cover.
Multipurpose key FIG 8, 8a
The insert is equipped with an handle, which is intended
for operating vents.

Operational control

When the insert is in upright position, and prior
to mounting the surround, control that all functions
are easy to maneuver and appear satisfactory. See also
FIG 8 & FIG 8a
FIG A
A. Ignition vent control
Pushed in = closed
Pull out = open
Removing the self-closing door mechanism FIG 16
In order to deactivate - follow instruction below:
- open the door,
- lock the spring by fastening the screw - A,
- lift the door up and unfasten the screw - B,
when a noise could be heard the self-closing door is
deactivated,
- lower the door back to its place - C.
Painting the surround
It is recommended to use the insert a few times in order
to let the varnish harden before any eventual masking
and painting. Only use water based breathing paint and
a designated masking tape. Carefully remove the tape
in order not to damage the varnish.
5. Lighting a fire for the first time
When the insert is assembled and all instructions have
been observed, a fire can be lit.
Take care when inserting logs into the burn chamber, in
order not to damage the Thermotte plates.
This will be resolved once the humidity has evaporated.
FIG B
B. Air vent control
Left position = closed
Right position = open
If needed leave the door slightly open the first 2-3 times
the insert is used.
It is advisable to ventilate the room well when using
for the first time as the varnish on the product may
release some smoke or smell. Both the smoke and
smell will disappear and are not hazardous.
In order to avoid injuries, please be aware that the
surfaface may become hot during operation and
extra care need to be taken to avoid skin burn.
Kindling wood
Finely chopped (diameter of 3-5cm)
Length: 25-30cm
Ca. amount pr lighting : 2,1 kg (beech)
Place the air vent control in ignition (FIG A) (Pull out).
Insert small, dry pieces of wood, ignite and ensure the
flames have taken proper hold of the wood. When the
flames are stable and the chimney is warm, push in the
air control out of the ignition mode and regulate the fire
normally.
When there is a glowing layer of ash, new wood logs
can be inserted. Pull the hot ember to the sides of the
combustion chamber when inserting new logs so that
the wood is ignited from the bottom. Insert 2 logs. One
positioned diagonally to the bottom with left end closer
to left front side of window pane. The second leaned
against first one also diagonally in opposite direction.
Set the air vent on 45% air valve opening. The fire
should burn with bright and lively flames.
Reload size
Chopped wood - 2 logs (diametre of 6-9cm)
Length: 25-30cm
Normal load size. 1,46 kg /h
(Max load size: 2,5 kg/h)
Attention!
Using the insert with low combustion effect and firing
around the clock increase pollution as well as the risk
for a fire in the chimney. Never allow the insert or flue to
become glowing red. Turn off the air vent control should
this happen. Regulation of the air vent control takes
some experience, but after a little while a natural rhythm
for the fire will be found.
IMPORTANT! Always remember to open
the air vent control (preferably also the door)
before new wood logs are inserted into a hot burn
chamber. Let the flames get a good grip on the
wood before the air control setting is reduced.
When the draught in the chimney is low and
the vent is closed, the gas from the firewood
can be ignited with a bang. This can cause
damage to the product as well as the immediate
GB
Warning!
environment.