Mounting the V-Flap
Installation of the hood for
recirculation mode
Mounting the hood for exhaust
air operation
Before beginning, make sure the power supply is secure. This must be set up by a specialist.
Attention! Before installing the hood, insert the V-Flaps as described below:
Montage der Ventilklappen:
If the valve flaps are not factory-mounted:
• First install half part 1 in connection nozzle B10
• Pins 3 must be in upwards position.
• Insert the axle 4 into the holes 5 on the nozzle B10.
• Repeat all operations for mounting the half part 2.
Montage der Haube für Umluftbetrieb:
1. Using pencil, draw a horizontal line at the height on the wall on which the hood
bottom edge should lie. (It is best to use a water level) Attention! Observe minimum
distance according to chapter 11.1 of the operating instructions.
2. Hold the supplied drill template with the bottom edge on the drawn pencil line
against the wall and mark the four drill holes. (Fig. a)
3. Drill a 30mm deep hole in the wall with an 8mm masonry drill at the 4 pencil marks.
For safety, check the diameter of the plugs with a caliper gauge.
4. Place one plug into each of the 4 holes.
5. Screw one ST4 × 30mm screw each into the two dowels for the hood suspension
(Fig. a2) Attention! The screw heads must protrude 3 - 5 mm from the dowels so that
the hood can be hung on them. (Readjust after the hood has been hung up)
6. Hang the hood with the two eyelets on its back (Fig. b) by the two screws on the
wall.
7. Mount the stabilizer- and mounting plate at the top of the lower flue with two ST4 *
8mm screws (Fig. c)
8. Place the lower chimney shaft on the hood.
fi200507ATL
Page
2
2 - 3
4
B 10
2 / 4
Fig. a)
Fig. a2)
Fig . b)
Abb. c)