Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; What To Do If - Becker Centronic SunWindControl SWC442-II Montage- Und Betriebsanleitung

Fur sonnen-wind-licht-steuerung
Vorschau ausblenden Andere Handbücher für Centronic SunWindControl SWC442-II:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembly and Operating Instructions
Nominal voltage
Type of battery
Protection class
Permissible surrounding temperature
Radio frequency
Problem
Drive is not function-
ing.
Automatic control
commands are not
executed.
The system is not
extended automatically
when the sliding switch
is set to "S".
The system does not
extended manually
when the sliding switch
is set to "H" or "S".
Lighting set is switched
on when a travel button
is pressed.
22

Technical data

What to do if ...?
Cause
1. Battery is flat.
2. Battery is inserted
incorrectly.
3. Receiver outside the
radio range.
4. Transmitter is not
programmed in the
receiver.
Sliding switch not in the
"H" position.
1. Sunlight intensity is
below the threshold
value.
2. Wind speed exceeds
threshold value.
Wind speed exceeds
threshold value.
Incorrect allocation of
the transmitter and the
receiver.
3 V DC
CR 2430
IP 20
-10 to +55 °C
868.3 MHz
Remedy
1. Insert new battery.
2. Insert battery cor-
rectly.
3. Reduce distance to
the receiver.
4. Programme transmit-
ter.
Set sliding switch to the
"S" position.
1. Adjust sun threshold
value.
2. Wait until wind abates.
Wait until wind abates.
Relearn the light function.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis