WARNING
If the device loses oil, send it to Weidmüller's customer service immediately.
Hydraulic oil constitutes a hazard to the environment.
If the servive LED lights up, the device must be sent to Weidmüller's customer
service for servicing.
In case the sealing label is damaged because the power tool is opened, the warranty
gets void.
Have your power tool serviced only by qualified repair personnel, and using
only original spare parts.
This will ensure that the safety of power tool is maintained.
Never service damaged batteries.
Any battery servicing should be carried out only by the manufacturer or by authorized
Weidmüller service representatives.
5.

Conduct in case of faults

5.1

Error codes of the operating/service LED display

In case of any fault, the EPG 60 Power Tool will be switched off and remain disabled. The service
LED will glow red or orange. You can proceed with your work only after the battery has been
exchanged or removed for short time and is then re-inserted (RESET). If the malfunction persists
even after such a "reset", please contact Weidmüller's after-sales service.
LED-Display
after application (cycle)
steady green
flashing red/green
flashing red
steady red
steady orange
after power on (battery insertion)
steady green
steady orange
steady red
The fault massages can be read out using the analysis software. Please return the faulty working
diagrams to our service center.
2515710000/00/04.2017
Cause / remedy
Working value OK
Working value OK but service interval exceeded / Service
Working value is at the limit / contact the service center
Working value is outside range /
return device to customer service
Temperature is outside the tolerance range /
cool or warm the device
Power tool is ready for operation
Temperature is outside the tolerance range /
cool or warm the device
Battery empty / change the battery.