5.

Conduct in case of faults

5.1

Error codes of the operating/service LED display

In case of any fault, the EPG 45 Power Tool will be switched off and remain disabled. The service
LED will glow red or orange. You can proceed with your work only after the battery has been
exchanged or removed for short time and is then re-inserted (RESET). If the malfunction persists
even after such a "reset", please contact Weidmüller's after-sales service.
LED-Display
after application (cycle)
steady green
flashing red/green
flashing red
steady red
steady orange
after power on (battery insertion)
steady green
steady orange
steady red
The fault massages can be read out using the analysis software. Please return the faulty working
diagrams to our service center.
5.2

Error codes of the supply voltage LED

Failure
after application (cycle)
flashing red
steady red
after power on (battery insertion)
steady green
steady red
2527090000/01/04.2017
Cause / remedy
Working value OK
Working value OK but service interval exceeded / Service
Working value is at the limit / contact the service center
Working value is outside range /
return device to customer service
Temperature is outside the tolerance range /
cool or warm the device
Power tool is ready for operation
Temperature is outside the tolerance range /
cool or warm the device
Battery empty / change the battery.
Cause / trouble shooting
Battery charge is below 10% / Change the battery.
Battery empty / change the battery.
Power tool is ready for operation
Battery empty / change the battery.