4. Spare parts

Only original Weidmüller spare parts may be used.
Battery:
Battery charger:

5. Conduct in case of faults

In case of any fault, the Power Tool will be switched off and remain disabled. The service
LED will glow red or orange. You can proceed with your work only after the battery has been
exchanged or removed for short time and is then re-inserted (RESET). If the malfunction
persists even after such a "reset", please contact Weidmüller after-sales service.
5.1 Codes of the operating/service LED display
LED-Display
after application (cycle)
steady green
flashing red/green
flashing red
steady red
steady orange
after power on (battery insertion)
steady green
steady orange
steady red
The fault massages can be read out using the analysis software. Please return the faulty
working diagrams to our service center.
5.2 Codes of the supply voltage LED
LED-Display
after application (cycle)
flashing red
steady red
after power on (battery insertion)
steady green
steady red
16
RA20
LG8
Cause / remedy
Working value OK
Working value OK but service interval exceeded / Service
Working value is at the limit / contact the service center
Working value is outside range / return device to customer service
Temperature is outside the tolerance range /
cool or warm the device
Power tool is ready for operation
Temperature is outside the tolerance range /
cool or warm the device
Battery empty / change the battery.
Cause / remedy
Battery charge is below 10% / Change the battery.
Battery empty / change the battery.
Power tool is ready for operation
Battery empty / change the battery.