8.8.3.6

Beispiel: Preset single register FC6

Konfiguration
SPS sendet zum UNIGATE
01 00 00 00 00 00 00
FF23
®
UNIGATE
sendet Modbus RTU Request
[01] [06] [00] [05] [ff] [23] [99] [e2]
Modbus Slave sendet Response
[01] [06] [00] [05] [ff] [23] [99] [e2]
Speicherinhalt von Modbus Slave nach Response:
8.8.3.7

Beispiel: Force multiple coils FC15

Konfiguration
Feldbus Master sendet:
0E 00 FF 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00...
®
UNIGATE
sendet Request:
[01] [0f] [00] [02] [00] [0a] [02] [ff] [05] [65] [29]
Modbus Slave sendet Response:
[01] [0f] [00] [02] [00] [0a] [74] [0c]
15.01.20
UNIGATE
®
00 FF 00 00 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 00 00 00 ...
®
Feldbus Gateway UNIGATE
Implementierte Protokolle im UNIGATE® MB
®
MB - MPI V. 1.6