Specifications
Model Name
Europe
Power source
Cooling capacity
Heating capacity
Sound Pressure level
(Cooling / Heating)
Sound Power level
(Cooling / Heating)
Unit Dimensions
(H×W×D)
Net weight
Operation condition temperature range
• Cooling mode : -15°C~46°C DB • Heating mode : -20°C~18°C WB / -20°C~24°C DB
Model Name
Europe
Power source
Model Name
Oceania
Power source
Cooling capacity
Heating capacity
Sound Pressure level
(Cooling / Heating)
Sound Power level
(Cooling / Heating)
Unit Dimensions
(H×W×D)
Net weight
Operation condition temperature range
• Cooling mode : -15°C~46°C DB • Heating mode : -20°C~18°C WB / -20°C~24°C DB
Rated conditions
Cooling : Indoor intake air temp. 27°C DB / 19°C WB. Outdoor intake air temp. 35°C DB.
Heating : Indoor intake air temp. 20°C DB. Outdoor intake air temp. 7°C DB / 6°C WB.
84

Outdoor unit

Single Split Outdoor Unit (R410A)
U-36PE2E5A
U-50PE2E5A
220 - 230 - 240 V ~ 50 Hz
3.6
kW
12,300
17,100
BTU/h
4.0
kW
13,600
19,100
BTU/h
45 / 46
46 / 48
dB(A)
64 / 66
65 / 68
dB(A)
619×799×299 619×799×299 619×799×299
mm
39
kg
U-71PE1E5A
U-60PE1R5A
U-71PE1R5A
6.0
kW
20,500
24,200
BTU/h
7.0
kW
23,900
27,300
BTU/h
48 / 50
48 / 50
dB(A)
65 / 67
65 / 67
dB(A)
996×940×340
996×940×340 1,416×940×340 1,416×940×340 1,416×940×340
mm
68
kg
U-60PE2E5A
5.0
6.0
20,500
5.6
7.0
23,900
46 / 49
65 / 69
39
40
U-100PE1E5A U-125PE1E5A U-140PE1E5A
220 - 230 - 240 V ~ 50 Hz
U-100PE1R5A U-125PE1R5A U-140PE1R5A
230 - 240 V ~ 50 Hz
7.1
10.0
34,100
8.0
11.2
38,200
52 / 52
69 / 69
69
98
12.5
14.0
42,700
47,800
14.0
16.0
47,800
54,600
53 / 53
54 / 55
70 / 70
71 / 71
98
98