The human activity sensor will also scan for area of heat source and movement in a room.
• Based on area activeness horizontal airfl ow direction louver will adjust either fi x at
predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit location, movement speed, temperature range,
etc.
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor's detection
area. They may cause sensor malfunction.
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
COOL/DRY
Set
temperature
HEAT
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.

Operation conditions

Use this air conditioner under the following temperature range.
DBT: Dry bulb temperature / WBT: Wet bulb temperature

Outdoor unit

CU-2E15PBE, CU-2E18PBE,
CU-3E18PBE, CU-4E23PBE,
CU-4E27PBE, CU-5E34PBE,
CU-2E12SBE, CU-2E15SBE,
CU-2E18SBE, CU-3E23SBE
COOL
HEAT
-1 °C
Indoor
DBT WBT DBT WBT
Max.
32
23
Min.
16
11
Max.
30
-
Min.
16
-
°C (temperature)
Detection area
+1 °C
Outdoor
46
26
-10
-
24
18
-15
-16
120º
7m
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
-1 °C
9