Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman DVM1100 Bedienungsanleitung Seite 11

Vorschau ausblenden Andere Handbücher für DVM1100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Resistance
Function
Resistance
Overload Protection: 1,000VDC or 1,000VAC RMS
Diode
Function
Diode test
Forward DC Current: ± 1mA
Reverse DC Voltage: ± 1.5V
Overload Protection: 1,000VDC or 1,000 VAC RMS
Continuity Check
Function
Continuity beeper: ≤ 75
Overload Protection: 1,000VDC or 1,000VAC RMS
Temperature
Function
Celsius
1
Temperature specifications do not include thermocouple errors
1
Overload Protection: 1,000VDC or 1,000VAC RMS
Capacitance
Function
Capacitance
Overload Protection: 1,000VDC or 1,000VDC
DVM1100
Range
400.0
4.000k
40.00k
400.0k
4.000k
40.00M
Range
1V
Range
400
Range
-55C°~0°C
1°C~400°C
401°C~1,000°C
Range
50nF
500nF
5µF
50µF
100µF
- 11 -
Resolution
0.1
1
10
100
1k
10k
Resolution
0.001V
Resolution
0.1
Resolution
0.1°C
1°C
Resolution
< 10nF: ± 5.0% - 50 digits
10pF
100pF
1nF
10nF
100nF
Accuracy
± 0.5% + 3 digits
± 0.5% + 2 digits
± 1.5% + 3 digits
Accuracy
1.0% uncertainty
Test Condition
Open circuit voltage
approx. 0.5V
Accuracy
± 9.0% + 2°C
± 2.0% + 1°C
± 2.0%
Accuracy
± 3.0% + 10 digits
± 3.0% + 5 digits
VELLEMAN