Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Cleaning And Maintenance - EuroLite FL-300 Flame-Light Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für FL-300 Flame-Light:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Mounting
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
Do only use appropriate screws and make sure that the screws are properly connected with the ground.

OPERATION

Before starting operation make sure that the silk cannot be drawn into the intake of the ventilation fan. With
the POWER-switch, you can switch the device on and off.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
There are no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service
operations are only to be carried out by authorized dealers.
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
8

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis