Herunterladen Inhalt Inhalt Diese Seite drucken

Led Information Panel - Mennekes AMTRON Compact 2.0 11 Betriebs Und Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Inside view
6
5
4
Fig. 4: Inside view
1
Cable glands *
2
Terminals
n 1 and 2: Enable input
n 3 and 4: Downgrade input
n 5 and 6: External shunt release switching
output
3
MCU (MENNEKES Control Unit)
4
DIP switch
5
Connection for the MENNEKES configuration
lead
6
Terminals for voltage supply
* Additional cable glands are installed on the top
and bottom.
3.5

LED information panel

The LED information panel shows the operating
status of the product (e.g. standby, fault).
8
1
2
3
Standby
Symbol
Meaning
lights up The product is ready for use. No
vehicle is connected to the product.
flashes
Not all requirements for charging are
slowly
met, e.g.
n The authorisation process is com-
plete. No vehicle is connected to the
product.
n A vehicle is connected to the
product. The downgrade input is act-
ive and configured to 0 A.
flashes
A vehicle is connected to the product.
rapidly
Authorisation has not occurred.
Colour of the symbol: blue or green (dependent on
the configuration)
In Standby operating mode, the product can switch
to Sleep mode after 10 minutes to reduce internal
consumption. The Sleep mode is configurable and
is enabled in the delivery state. It is terminated by
plugging in the charging cable or by an authorisa-
tion. In Sleep mode, no symbol lights up on the LED
information panel.
Charging
Symbol
Meaning
lights up The charging process runs.
flashes
The operating temperature is very high.
slowly
The charging process runs. The char-
ging current is reduced to avoid over-
heating and shutting down the product.
flashes
The operating temperature has been
rapidly
exceeded. Charging process paused.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Amtron compact 2.0 22

Inhaltsverzeichnis