1.1 Compliance
The stove is built in compliance with standard EN 14785, CE and Ecodesign 2022 is thereby approved for
installation and use in Europe. Meanwhile, the manufacturing process is subject to external quality control.
DoP (Declaration of Performance) can be downloaded at www.adurofire.com/download.
Retain this manual for future reference. For any requirement or clarification,
please contact the authorised retailer.

1.2 Safety warnings

We recommend that the installation and connection is carried out by an authorized service partner in
compliance with local regulation, national and European standards and with the annexed installation
instructions.
During transportation, it may happen that the baffle plate in steel falls out of place. Therefore, before
using the pellet stove, please make sure that the baffle plate is properly placed on the screws for
optimum combustion and for preventing soot on the glass. The baffle plate is located at the bottom
front of the stove behind the cover plate which is secured by four hand screws. Unscrew the four
screws to check that the baffle plate is correctly placed on the two screws inside.
The combustion of waste, especially of plastic materials, damages the stove and the flue pipe.
Moreover, it is forbidden by the law against the emission of harmful substances.
Use only the fuel recommended by Aduro A/S. It is forbidden to use any liquid fuels and bioethanol
fluids for lighting/rekindling pellets.
Do not introduce a greater amount of pellets into the stove than the amount recommended (see
below).
It is forbidden to use the stove with the door open or the glass broken.
Do not use the stove as, for example, a clothes' drying rack or bearing surface.
Do not install the stove in bathrooms.
The pellets to be used are the following:
The pellet stoves operate exclusively with wood pellets complying with the standards DIN plus or EN
plus 14961-2 A1 or PEFC/04-31-0220 or ONORM M7135 or having the following characteristics:
Min calorific value 4.8 kWh/kg (4180 kcal/kg)
Density 630-700 kg/m3
Maximum humidity: 10% of the weight
Diameter: 6 ±0.5 mm
Percentage ash: max 1% of the weight
Length: min 6 mm - max 30 mm
Composition: 100% untreated wood from the industry of wood or post-consumption without the
addition of binders, bark-free and compliant with current regulations.