10.4 Tabelle mit IO-Link Device
Diagnose-Codes
Diagnose-Code
Definition
0x5100
General power supply fault – Check availability
0x5101
Fuse blown/open – Exchange fuse
0x5102 to 0x510F
Reserved
0x5110
Primary supply voltage overrun – Check tolerance
0x5111
Primary supply voltage underrun – Check tolerance
0x5112
Secondary supply voltage fault (Port Class B) – Check
tolerance
0x5113 to 0x5FFF
Reserved
0x6000
0x6001 to 0x631F
Reserved
0x6320
Parameter error – Check data sheet and values
0x6321
Parameter missing – Check data sheet
0x6322 to 0x634F
Reserved
0x6350
Reserved
0x6351 to 0x76FF
Reserved
0x7700
Wire break of a subordinate device – Check installation
0x7701 to 0x770F
Wire break of subordinate device 1 ...device 15 – Check
installation
0x7710
Short circuit – Check installation
0x7711
Ground fault – Check installation
0x7712 to 0x8BFF
Reserved
0x8C00
Technology specific application fault – Reset Device
0x8C01
Simulation active – Check operational mode
0x8C02 to 0x8C0F Reserved
0x8C10
Process variable range overrun – Process Data uncertain
0x8C11 to 0x8C1F
Reserved
0x8C20
Measurement range exceeded – Check application
0x8C21 to 0x8C2F Reserved
0x8C30
Process variable range underrun – Process Data uncertain
0x8C31 to 0x8C3F Reserved
158
10 Diagnose
Typ
Error
Error
Warning
Warning
Warning
Error
Error
Error
Error
Error
Error
Error
Warning
Warning
Error
Handbuch PROFINET
Version 2.0 03/2022