Herunterladen Inhalt Inhalt Diese Seite drucken

Benning Profipol Bedienungsanleitung Seite 2

Spannungsprüfer
Vorschau ausblenden Andere Handbücher für Profipol:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Bedienungsanleitung
D
Operating manual
F
Mode d'emploi
E
Manuel de instrucciones
Инструкция за експлоатация
Návod k použití zkoušečky
Brugsanvisning
Käyttöohje
Οδηγίες χρήσεως
Használati utasítás
H
Istruzioni per l'uso
I
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Münsterstraße 135 - 137 • D - 46397 Bocholt
Phone: +49 (0) 2871 - 93 - 0 • Fax: +49 (0) 2871 - 93 - 429
www.benning.de • E-Mail: duspol@benning.de
Naudojimosi instrukcija
Bruksanvisning
N
Gebruiksaanwijzing
Instrukcja obsługi
Instrucţiuni de utilizare
Инструкция по эксплуатации
индикатора напряжения
S
Bruksanvisning
Kullanma Talimati
Priručnik za upotrebu
3
4
5
A
B
6
Operating manual
PROFIPOL
®
Before using the voltage tester PROFIPOL
Please read the operating manual carefully and
always observe the safety instructions!
List of contents:
1.
Safety instructions
2.
Functional description of the voltage tester
3.
Functional test of the voltage tester
4.
How to test AC voltages
5.
How to test DC voltages
5.1 How to test the polarity at DC voltage
6.
Technical data
7.
General maintenance
8.
Environmental notice
1.
Safety instructions:
-
Hold the voltage tester only by the insulated han-
dles
and
and do not touch the contact elec-
trodes (probe tips) !
-
Immediately before use: Check the voltage tester
for correct operation! (see chapter 3). The voltage
tester must not be used if one or several display
functions fail or if the voltage tester is not ready to
operate (DIN EN 61243-3:2011)!
-
The voltage tester must be used only within the
nominal voltage range of 6 V up to 400 V!
-
The voltage tester must be used only in electric
circuits of overvoltage category CAT III with max.
300 V for phase-to-earth measurements.
-
The voltage tester complies with protection class
IP 65 and therefore can also be used under wet
conditions.
-
For testing, firmly grasp the voltage tester by the
handles
and
.
-
The voltage tester is designed for being used by
qualified electricians and under safe working con-
ditions.
-
The LED step indicator is intended for indicating
the voltage range. It is not intended for measuring
purposes.
-
Typical values of noise voltages are not displayed,
they are suppressed.
-
Never connect the voltage tester to voltage for
longer than 30 seconds (maximum permissible
operating time = 30 s)!
-
The voltage tester only operates correctly
within the temperature range of - 15 °C up to
+ 55 °C at relative air humidity of 20 % up to
96 %.
-
Do not dismantle the voltage tester!
-
Please protect the housing of the voltage tester
against contamination and damages.
-
Please store the voltage tester under dry conditions.
Attention:
After maximum load (i.e. after a measurement of 30
seconds at 400 V), the voltage tester must not be used
for a duration of 300 seconds!
Electrical symbols on the device:
Symbol
Meaning
Important documentation!
The symbol indicates that the guide
described in the manual, to avoid any
risks
Device or equipment for working under
voltage
Direct and alternating voltage (DC/AC)
Earth (voltage to ground)
2.
Functional description
The PROFIPOL
is a two-pole voltage tester accord-
®
ing to DIN EN 61243-3:2011 with visual display 
and without own power supply. The voltage tester is
designed for DC and AC voltage tests within the volt-
age range of 6 V up to 400 V. It can be used to per-
form polarity tests in DC.
The voltage tester consists of the test probes L1
and L2
and a connecting cable 6. The test probe
L1
is equipped with a display .
Display field
The display system  consists of high-contrast light-
emitting diodes (LED) 3 indicating voltages in steps
of 6 V to 400 V. The indicated voltages are nominal
voltages. With DC voltage, the LEDs also indicate the
polarity (see chapter 5).
3.
Functional check
-
The voltage tester must be used only within the
nominal voltage range of 6 V up to 400 V!
-
Never connect the voltage tester to voltage for
longer than 30 seconds (maximum permissible
operating time = 30 s)!
-
Check the voltage tester for correct function
®
:
immediately before use!
-
Test all functions by means of known voltage
sources.
For DC voltage tests use e.g. a car battery.
For AC voltage tests use e.g. a 230 V socket.
Do not use the voltage tester unless all functions are
operating correctly!
4. How to test AC voltages
-
The voltage tester must be used only within the
nominal voltage range of 6 V up to 400 V!
-
Never connect the voltage tester to voltage for
longer than 30 seconds (maximum permissible
operating time = 30 s)!
-
Place the contact electrodes  of the test probes
L1
and L2
against the relevant points of the
unit under test.
-
For AC voltages from 6 V onwards the LEDs
"plus" and "minus" 4 and 5 light up. Further-
more, all LEDs light until the step value of the
applied voltage is reached.
5.
How to test DC voltages
-
The voltage tester must be used only within the
nominal voltage range of 6 V up to 400 V!
-
Never connect the voltage tester to voltage for
longer than 30 seconds (maximum permissible
operating time = 30 s)!
-
Place the contact electrodes  of the test probes
L1
and L2
against the relevant points of the
unit under test.
-
For AC voltages from 6 V onwards the LEDs
"plus" and "minus" 4 and 5 light up. Further-
more, all LEDs light until the step value of the
applied voltage is reached.
5.1 How to test the polarity at DC voltage
-
The voltage tester must be used only within the
nominal voltage range of 6 V up to 400 V!
-
Never connect the voltage tester to voltage for
longer than 30 seconds (maximum permissible
operating time = 30 s)!
-
Place the contact electrodes  of the test probes
L1
and L2
against the relevant points of the
unit under test.
-
If LED 4 lights up, the "positive pole" of the unit
under test is at test probe
.
-
If LED 5 lights up, the "negative pole" of the unit
under test is at test probe
.
6.
Technical data
-
Guideline for two-pole voltage testers: DIN EN
61243-3:2011
-
Protection class: IP 65, IEC 60529 (DIN 40050)
IP 65 means: Protection against access to danger-
ous parts and protection against solid impurities,
dustproof, (6 - first index). Protected against water
jets, (0 - second index).
-
Nominal voltage range: 6 V to 400 V
-
Internal resistance, measuring circuit: 130 kΩ
-
Current consumption: max. I
3.1 mA
n
-
Polarity indication: LED +; LED -
(indicating handle = positive polarity)
-
Indicating steps LED: 6 V, 12 V, 50 V, 120 V, 230 V,
400 V
-
max. indicating errors: U
± 15 %, ELV U
n
-
Nominal frequency range f: 0 to 500 Hz
-
max. permissible operating time:
ED = 30 s (max. 30 seconds), 300 s pause
-
Weight: approx. 136 g
-
Connecting cable length: approx. 830 mm
-
Operating and storing temperature range: - 15 °C
up to + 55 °C (climate category N)
-
Relative air humidity: 20 % up to 96 % (climate
category N)
7.
General maintenance
Clean the exterior of the housing with a clean dry cloth
(exception: special cleansing cloths). Do not use sol-
vents and/ or abrasives to clean the voltage tester.
8.
Environmental notice
At the end of the product's useful life, please
dispose of it at appropriate collection points
provided in your country.
- 15 %
n

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis