The guarantee DOES NOT cover defects or damage resulting from abuse or failure to follow the
user instructions. The guarantee becomes void if the device is opened, tampered with, or used with
non-Braun branded parts or accessories, or if repairs are undertaken by unauthorized persons.
Accessories and consumables are excluded from any warranty.
For support requests, please visit www.braunhealthcare.com/uk_en/ or find contact information at
the end of this owner's manual.
This Guarantee is applicable to Europe, Russia, Middle East and Africa only.
UK Only: This does not affect your consumer statutory rights.

Errors and troubleshooting

Error message
Situation
When 20% of battery life is left, the
display flashes the low battery
warning symbol; however, the device
can still work until the battery life has
0% left.
If the steady battery icon is
the only symbol shown on the display,
the device cannot work. The battery
should be replaced immediately.
This message displays when the
measured temperature is lower than
34°C (93.2 °F) or higher than 43 °C
(109.4 °F) or when the room
temperature is outside the operating
range of 15 °C – 40 °C (59 °F – 104 °F).
Blank display. Thermometer does not
have power.
System error (All icons display or
display is blank)

Care and cleaning

Use an alcohol swab or cotton swab moistened with alcohol (70% isopropyl) to clean the
thermometer casing and the measuring scanner area. Ensure that no liquid enters the interior of
the thermometer. Never use abrasive cleaning agents, thinners or benzene for cleaning and never
8
Solution
Replace batteries.
Replace batteries.
Re-measure the temperature,
carefully following the instructions
in "How to use" section.
Please check if the batteries have
been loaded correctly. Also check
polarity (<+> and <–>) of batteries.
Contact Consumer Services if
thermometer still does not function.
Reset the thermometer by removing
the batteries and putting them back
in. Batteries may need to be
replaced with new batteries. If error
persists, contact Customer Service.
immerse the instrument in water or other cleaning liquids. Wait 10 minutes after cleaning before
taking a temperature measurement. Make sure to replace the protective cap after use to prevent
scratches or damage from occurring to the thermometer.
Never insert a sharp object into the scanner area or any other open surface on the thermometer.

Replacing the batteries

The No touch + touch thermometer comes with 2 AAA batteries. Replace with 2 new AAA batteries
when the flashing battery symbol appears on the LCD display. To change the batteries, slide open
the battery cover and remove batteries. Replace the batteries being sure to align properly as
indicated inside the battery compartment. Remove the battery from the product if it is not required
for extended periods of time in order to avoid damage to the thermometer resulting from a leaking
battery.
To protect the environment, dispose of empty batteries at appropriate collection sites
according to national or local regulations.

Product specifications

Type:
No touch + touch thermometer (BNT300)
Measuring range:
34 °C – 43 °C (93.2 °F – 109.4 °F)
Resolution:
0.1 °C (0.1 °F)
Laboratory Accuracy:
±0.2 °C for the range 35 °C – 42 °C (±0.4 °F for 95 °F – 107.6 °F)
±0.3 °C (outside this temperature range)
(Ambient Temperature: 15 °C to 40 °C (59 °F to 104 °F))
Display:
Liquid Crystal Display, 4 digits plus special icons
Acoustic:
Audio:
Normal temp range = single long beep for 2 sec duration
Fever = Red or Yellow temp range: 10 short beeps
Operating temperature:
15 °C – 40 °C (59 °F to 104 °F)
Automatic Switch-off:
Approx. 60 seconds after last measurement has been taken
Weight:
101 g ± 10 g (with batteries), 80 g ± 10 g (w/o batteries)
Long term storage ranges
Storage/transport temperature:
-25 °C to 55 °C (-13 °F – 131 °F)
Humidity:
15–95% non-condensing
Battery:
(2) AAA Batteries - 2 yrs and 500 readings
Pressure:
700-1060 hPA (0,7-1,06 atm)
The No touch + touch thermometer measures infrared energy radiated from the skin at the center
of the forehead. This captured energy is collected through the lens and converted to an oral
equivalent value.
Clinical accuracy and procedures are available upon request.
This medical device carries the CE mark and is manufactured in conformity with RoHS Directive
2011/65/EU and other applicable directive and/or regulations as specified in the EU Declaration of
Conformity. This infrared thermometer meets requirements established in ASTM Standard E
1965-98 for the thermometer system. Full responsibility for the conformance of the product to the
standard is assumed by Kaz Europe Sàrl, Place Chauderon 18, CH-1003 Lausanne, Switzerland.