TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 AND 2015/1186
Manufacturer
Trademak
Model Identifier
Description
Indirect heating functionality
Direct heat output (space heat output)
CPR harmonised standard
Notified Body
Fuel
Compressed wood with moisture content < 12 %
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the product
Up to 1/1/2022
[%]
s
EEI [%]
Energy Efficiency Class
Calculations according to the council commission regulation (EU) 2015/1186 and 2015/1185
Characteristics when operating with the preferred fuel
10
Heat output
Item
Nominal heat output
Minimum heat output
(indicative)
Auxiliary electricity consumption
Item
At nominal heat output
At minimum heat
output
In standby mode
F(4)
Contact details
Name and address of the manufacturer
EDILKAMIN S.p.A.
Via Mascagni 7
20045 Lainate (MI) – ITALY
TECHNISCHE DATEN ECODESIGN
Preferred fuel
(unique)
yes
87,0
128
A+
Symbol
Value
Unit
P
11,4
kW
nom
P
3,6
kW
min
Symbol
Value
Unit
el
0,217
kW
max
el
0,070
kW
min
el
0,003
kW
sb
2,3 %
CC =2,5
BENUTZER/INSTALLATEUR
Edilkamin S.p.A.
Edilkamin
Cherie Evo 11 Air Tight C
Mechanically space heater fired by wood pellets
no
11,4 kW
EN 14785
Acteco srl (Via Amman 41 ,33084 Cordenons-PN-Italy) NB1880
Space heating emissions at nominal heat output
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides
PM
OGC
CO
mg/m3 at 13%O2
15
2
19
From 01/01/2022
[%]
87,0
s
EEI [%]
128
Energy Efficiency
A+
Class
BLF =1,45
F5 not of relevance
Useful efficiency (NCV as received)
Item
Useful efficiency at nominal
heat output
Useful efficiency at
minimum heat output
(indicative)
Type of heat output/room temperature control (select one)
single stage heat output, no room temperature
control
two or more manual stages, no room temperature
control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus day
timer
with electronic room temperature control plus
week timer
F (2)
F (2)
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window
detection
with distance control option
F (3)
F (3)
www.edilkamin.com
mail@edilkamin.com
Legal Representative
Paolo Gusella
Space heating emissions at minimum heat
output
Only required if correction factors F(2) or F(3) are applied.
NOx
PM
OGC
CO
NOx
mg/m3 at 13%O2
128
12
2
58
99
Symbol
Value
Unit
91,3
%
th,nom
95
%
th,min
NO
NO
NO
NO
NO
yes
7,0 %
up to 2022
7,0 %
from 2022
NO
NO
yes
1,0 %
up to 2022
1,0 %
from 2022

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cherie 11 evo air tight cCherie 9 evoCherie 11 evo812340-1136000812330-1136000