USE
This machine adopts a unique energy storage system. Please complete cold storage or heat storage in
advance before setting the cooling mode / strong cooling mode or heating mode.
1. Connect the power supply
1) For the first use, please connect the power supply and then refer to step 2 of "Water inflow".
2) When it is not used for the first time or there is water in the water tank, please insert the power plug
into the power socket and press the power button on the control panel.
2. Water inflow
In case of water shortage alarm (no water in the water tank during the first use or water shortage during
use), please follow the steps below to feed water into the water tank inside the machine.
1) Remove the water inlet knob at the back of the appliance by rotating it anti-clockwisely.
2) Use the water inlet/outlet pipe to connect the machine with faucet. Press the water inflow button
and the faucet should be turned on at the same time.
3) When the water level reaches the specified height, the water inlet valve will automatically close to
complete the water inlet.
4) Remove the water inlet/outlet pipe and screw back the water inlet knob.
3. Cold storage
1) Press the mode button to select the cold storage function.
2) Press the button "+" or "-" to set the cold storage temperature. The lower the setting temperature is,
the greater the storage capacity is. Set the temperature range between -6℃ and 5℃.
3) After the completion of cold storage, the unit will automatically enter the standby state.
Note:
During cold storage, the wind is at high speed and the swing blade is at the maximum outlet angle. At
this time, the heat energy will be discharged. In a narrow space, please open the doors and windows
for ventilation.
The actual temperature of water in the water tank is displayed during cold storage.
The air inlet and air outlet shall not be covered.
4. Cooling
Once the cold storage is finished:
1) Press the mode button to select the cooling mode.
2) Press the button "+" or "-" to set the cooling temperature, between 16℃ and 32℃.
3) Press the wind speed button to select the low / mid / high / automatic wind speed in 4 levels.
4) Press the swing button to turn on/off the swing function.
Note:
It displays the room temperature during cooling.
When the cooling capacity of the water in the water tank is used up (the water temperature reaches
40℃), the cooling shall be stopped, and the water can only be used after the cold storage or the
high-temperature water in the water tank is replaced.
5. Strong cooling
This mode can be used when fast cooling is required.
1) Press the mode button to select the strong cooling mode.