Warning! Keep the air intakes, supplying
combustion air, free from blockage.
If the requirements for ventilation are
NOT complied with, the product can overheat.
This can cause a fire.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.

3. Technical information

All products Nordpeis have secondary combustion and
are clean burning. The combustion takes place in two
phases: First the wood burns and then the gases from
the fumes are lit by the hot air. This ensures that these
new fireplaces have minimal emissions of soot particles
and un-burnt gases (such as CO) and are thus better
for the environment. Clean burning fireplaces require
a small amount of wood in order to obtain a good heat
output. Use exclusively clean and dry wood.
Weight incl.insert
Material insert
Insert
Surface treatment door/
doorframe
Fuel recommended
Nominal heat output
Efficiency
CO % @ 13% O
2
Draught system
Combustion system
Flue outlet
Flue
Flue gas temperature
at flue connector
Flue gas mas flow
Draft at flue connector
recommended
Flue gas temperature
Draft
Maximum fuel length
Fuel charge
Refueling interval
Opening of the air vent
control
Operation
* Intermittent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember
12
Low 228 kg / High 253 kg
Sheet steel / Colorado concrete
S-31A Exclusive
Heat resistant varnish
Wood logs, 25-30 cm
6 kW
> 65 %
<1500 mg/m³
Air vent control
Secondary combustion (clean
burning)
Top and rear
Outer Ø 150 mm
*Alternative versions exsists due
to National requirements
320 °C
5,2 g/s
>12 Pa
277 °C
12 Pa
30 cm
1.4 kg
50 min
33%
Intermittent*

4. Safety distances

Ensure that the safety distances are complied with
(FIG 2).
When connecting a steel chimney to the top outlet
follow the assembly instructions from the producer.
Ensure to comply with the security distances required
for the steel chimney.
5. Assembly
FIG 3 - 4a
Prepare the place where the roomheater is going to be
installed. Makes sure the surface is free of any dust and
concrete residue. Check by the level whether the body
and the base frame of the roomheater are in correct
position. If needed corect level using base feet.
Attention! If you plan utilize rear air connection cut out
the hole in the rear wall of the base.
Fresh air supply set (accessory)
Please note! If the fireplace is connected to a fresh
air supply set then the surround elements should be
prepared for this before assembly of basic the surround
begins. Fresh air supply can be connected through the
base plate or through one of the laterals of the base.
See FIG Quadro Colorado Exclusive Air.

Operating control

When the insert is in an upright position, and prior to
assembling the surround, control that all functions
are easy to manoeuvre and appear satisfactory.
Air vent control
Left
Right
Removing the self-closing mechanism FIG 29
A. Open the door and tighten the set screw using a
2,5 mm Allen Key.
B. Carefully push the door upwards
Loosen the set screw with the Allen key.
C. The door can now be lowered back into place
Attention! In some countries removing the self
closing mechanism is not allowed. Make sure you
follow the local rules and regulations regarding self
closing door.