Technical TABLE
Insert
Material
Surface treatment
Weight of insert (kg)
Draught system
Combustion system
Maximum fuel length (cm)
Flue outlet
Flue collar (Ø mm)
*alternate versions exists due to nationa requirements
Flue gas temperature at flue
connector (°C)
Draft at flue connector
recommended (Pa)
Data according to EN 13 229
Area of convection air vent under
insert (cm 2 )
Area of convection air vent over
insert (cm 2 )
Minimum distance conv. air outlet
to ceiling (mm)
Nominal heat output (kW)
Efficiency (%)
CO @ 13% O 2 (%)
Flue gas temperature (°C)
Draft (Pa)
Fuel recommended:
Fuel length recommended (cm)
Fuel charge (kg/)
Refueling interval (minutes)
Opening of the air vent
control (%)
Operation*
* Intermittent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember
Warning: If the requirements for ventilation are
NOT complied with, the cooling airflow around the
product will be considerably reduced and
the product can overheat.
This can cause a fire.

3. Safety distances

Firewall
Ensure that the minimum safety distances are fullfiled
(FIG 1).
When connecting a steel chimney to the top outlet use
the security distances required by the manufacturer.
12
N-29PX
Steel
Heat resistant varnish
162 kg
Ignition air vent control
and air vent control
Clean burning
50
Top and back
Outer 150
318
14-25
500
700
500/750
10
80
0,07
265
12
Wood logs
<50cm
3
45
30
Intermittent*
GB
Important! When placing the insert on
a combustible floor, a steel plate of at least
0.7mm must cover the entire floor surface inside
the surround. Any flooring made of combustible
material, such as linoleum, carpets etc. must be
removed from underneath the steel plate.
The insert expands when in use, and for
this reason the surround must NEVER rest
on the insert, but have a gap of about 3 mm.
The insert must neither rest on the bench plate or
against the sides. It is recommended to dry stack
the surround in order to adjust the insert prior
to perforating the chimney for the flue connection.
4. Assembly
Removing the insert from the pallet FIG 2
Before the insert is removed from the pallet, remove the
accessories in the combustion chamber.
Attention! Our inserts are prepared for connecting
the smoke pipe on the outside of the flue collar Ø150.
*Alternative versions of the flue collar exist due to
National requirements. For the flue connection to the
chimney, follow the recommendations from the chimney
manufacturer.
Operational control
When the insert is in upright position, and prior to
mounting the surround, control that all functions are easy
to maneuver and appear satisfactory.
FIG A
A. Air vent control
Left position = closed
Right position = open
The air vent control is turned to the right to increase
the air supply. Normal working area is between the
minimum setting and the noticable click pushing it right.
Between the click and maximum right is kindling position.
IMPORTANT: Kindling position may only be used
during priming the insert. Continuous use may dam-
age the insert or overheat the installation and laead
to uncontrolled fire.