Preparations

– A water connection with G ½ inch internal thread and a thread length of at least 15 mm must be available for
installation (see Fig. 1).
– A correctly installed and earthed socket outlet must also be available.
– Mark and drill holes accordingly (see Fig. 2) and insert 6 mm dowels.
– Use a spirit level to ensure they are centred and horizontal!
Mounting wall
G ½"

Mounting

1. Remove cover (1). For this purpose, unhook the two detents
(2), i.e. press them gently away from the appliance with a
small screwdriver or your hand and lift off the cover.
2. With two fork wrenches size 30 and size 22 unscrew the
connection between the union nut ¾ inch (4) and the water
connection (5).
3. Screw in the water connection (5), using a size 22 fork
wrench. The gasket must be screwed into the thread
completely. Check the distance of 40 mm (Fig. 4). Direct
the valve (v) downwards so that it is still accessible after the
mounting of the device.
4. Introduce the swivelling spout (3) with gasket and snap ring
fully into the threaded connector so that the union nut can