10. TROUBLESHOOTING
POSSIBLE CAUSE
PROBLEM
Power cable not properly
connected.
The inflator
Undervoltage in battery.
does not start
Overvoltage in battery.
The ON button has not been pressed.
The safety fuse is blown.
The device is damaged
Hose wrong connection.
The inflator
does not
Wrong pressure setting.
inflate
Switch not in START position.
10.1 ONLY FOR TURBOMAX KIT 12V and TURBOMAX KIT 24V-EV
ASSEMBLING THE CONNECTOR
1.
Put the lids and the red grommets onto the cable ends (fig. 1).
After crimping the faston, we recommend you to tin the cable end to the connector to ensure current
flow (fig. 1 - arrow).
2.
Insert the fastons into their seats, checking coupling tooth (fig. 2) and polarity (fig. 4).
3.
Insert the grommets and the lids into their seats (fig. 3).
POWER CABLE
The cable section of the on-board supply system should be suitable for its length:
4.
For cable length up to 6 meters: 10 mm2 section
5.
For cable length from 6 to 12 meters: 16 mm2 section
16
POSSIBLE SOLUTION
Connect the power cable correctly
and with the right polarity (red clamp
to battery positive terminal).
Check battery conditions.
Check battery conditions.
Press the ON key.
Replace the fuse with one of the same
type (40 or 70 A).
Contact a SCOPREGA service
centre.
Connect the air hose to the
correct port.
Correct pressure setting.
Set main switches to ON and then
press START.
FASTENING THE INFLATOR
The inflator can be fastened onto the boat by means of the supplied "B" brackets (fig. 5). Otherwise, it
can be wall-mounted after drilling a hole (fig. 6), by fastening it to the "A" holes (fig. 5) by means of Ø
4.5 mm self-threading screws. The maximum screw length inside the inflator is 8 mm.
PREPARING THE INFLATION HOSE
Cut the hose to the desired size. Insert the red fitting into one of the hose ends to connect it to the
inflator.
At the opposite end, insert and glue the soft PVC reduction unit. Then insert the valve fitting, taking
care to select from the kit supplied the one that allows the valve to open fully.