Mounting
6.5 Electrical connection of the
charging station
DE
For the electrical connection of the charging station,
proceed as follows:
The supply line (supply) is fed through a cable
k
EN
gland (M25) from below. Insert the supply line and
connect it to the screwless terminal block (Klippon-
®Connect) of the charging station (see picture).
Use wire end sleeves (according to manufacturer's
instructions) for flexible conductors.
Tighten cable gland
k
charging cable
34
Check the sealing gap for possible foreign objects
k
and place the plastic cover on the plastic housing.
Fasten the plastic cover using the four metric
k
screws (max. 100 Ncm).
500 Ncm
incoming line (supply)
cable diameter 8-17 mm
3-phase supply
(L3, L2, L1, N, PE)
single phase supply
(L1, N, PE)