Heater must be placed on level firm ground.
-
Never operate heater in an explosive atmosphere like in areas where gasoline or other
flammable liquids or vapors are stored.
-
To protect heater from strong wind, anchor the base securely to the ground with screws.
-
Use propane, butane or their mixtures gas only.
-
The pressure regulator and hose assembly to be used must conform to local standard codes.
-
The installation must conform to local codes, or in the absence of local codes, with the
standard for the storage and handling of liquid petroleum gases.
-
A dented, rusted or damaged tank may be hazardous and should be checked by your tank
supplier. Never use a tank with a damaged valve connection.
-
The tank must be arranged to provide for vapor withdrawal from the operating cylinder.
-
Never connect an unregulated tank to the heater.
-
Gas connections on the heater are leak tested at the factory prior to shipment. A complete
gas tightness check must be performed at the installation site due to possible mishandling
in shipment or excessive pressure being applied to the heater.
-
Make a soap solution of one part liquid detergent and one part water. The soap solution can
be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
-
The heater must be checked with a full cylinder.
-
Make sure the safety control valve is in the OFF position.
-
Turn the gas supply ON.
-
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply
on and re- check.
-
Never leak test while smoking.
Do not attempt any changes to the device in any way to apply. Incorrect installation, improper use,
changes or modifications to the device may damage or cause injury. Manufacturer and importer
can not be held responsible.
1. Depress and turn control knob clockwise to OFF position.
2. Fully open gas valve.
3. Depress control knob and turn knob counter-clockwise to IGNITE position, then to PILOT
position (you will hear 2 clicks).
4. With the pilot light lit, keep control knob depressed for 30 seconds.
5. After depressing the control knob for 30 seconds, turn control knob to LOW. To increase the
temperature, turn towards HIGH.
If the pilot light has not ignited, turn heater control knob to OFF position, fully close gas valve, wait
Minimum distance must be 100 cm.

GAS REQUIREMENTS

LEAKAGE TEST
WARNING!
TO TURN ON THE HEATER
NOTE