HEATER STAND AND LOCATION
-
The heater is primarily for outdoor use only.
Always ensure that adequate fresh air ventilation is provided.
-
Always maintain proper clearance to combustible materials, i.e.
-
top 100cm and sides 100cm minimum.
Heater must be placed on level firm ground.
-
Never operate heater in an explosive atmosphere like areas
-
where gasoline or other flammable liquids or vapors are stored
GAS REQUIREMENTS
Use propane, butane, propane and butane mixture.
-
-
The pressure regulator and hose assembly must be used conform local standard codes.
-
Use correct pressure regulators conform to local regulation in force and specification of this manual.
-
The installation must be conform local codes, or in the absence of codes, with the standard for storage and
handling of liquid petroleum gases.
A dented, rested or damaged propane tank may be hazardous and should be checked by your tank supplier.
-
Never use a propane tank with a damaged valve connection.
-
The propane tank must be arranged to provide for vapor withdrawal from the operation cylinder.
-
Never connect an unregulated propane tank to the heater.
-
The rubber hose which connect the regulator and inlet should not be longer than 60 cm
-
-
The rubber hose should have CE approval, and heat resistance should be between 20℃ to 80℃
LEAKAGE TEST
-
Gas connections on the heater are leak tested at the factory prior to shipment.
-
A complete gas tightness check must be preformed at the installation site due to possible mishandling in
shipment or excessive pressure being applied to the heater.
The heater must be checked with a full cylinder.
-
Make sure the safety control valve is in the OFF position.
-
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with a
-
spray bottle, brush or rag.
-
Soap bubbles will appear in case of a leak.
-
Leakage test points. See pictures below.
.
www.sunred.nl