APPENDIX B - PARAMETERS BASED ON APPLICATION

DRV Group
When you want to change the frequency setting
When you want to change the acceleration and deceleration time of the motor
When you want to change the run/stop method
When you want to change the frequency reference source
When you want to set the multi-function
When you want to see the output current, motor speed and the DC link voltage of inverter
When you want to see the output voltage, output power, output torque from the user display
When you want to check the fault of the inverter
FU1 Group
When you want to use the Jump Code
When you want to prevent the motor from rotating at opposite directions
When you want to select the acceleration and deceleration pattern suitable for your application
When you want to change the stopping method
When you want to change the stopping accuracy for steady stop
When DC injection braking is required before starting
When you want to set the maximum frequency and the base frequency according to the rated torque of the
motor
When you want to adjust the starting frequency
When you want to limit the mechanical rotating speed to a fixed value
When a large starting torque is needed for loads such as elevators (Manual/Auto Torque Boost)
When you want to select an appropriate output characteristic (V/F characteristic) according to loads
When you want to se up your own V/F pattern
When you want to adjust the output voltage of the inverter
When you want to use the energy saving function
When you want to protect the motor from overheating
When you want to output a signal when the overload condition lasts more than a fixed amount of time
When you want to cut off the output when the overload condition lasts more than a fixed amount of time
When you want to set the stall prevention function
FU2 Group
When you want to check the fault history of the inverter
When you want to use dwell function
When you want to prevent the resonance from the oscillating characteristics of a machine
When you want to protect inverter from input/output phase loss
When you want to start the inverter as soon as the power is turned ON
When you want to restart the inverter by resetting the fault when a fault occur
When you want to use the instant power failure restart function (Speed Search)
When you want to use the retry function
When you want to enter the motor constants
When you want to reduce noise or leakage current by changing the PWM carrier frequency
When you want to change the control method (V/F, slip compensation, PID, or sensorless operation)
All manuals and user guides at all-guides.com
Intention
84
Parameter Code
DRV-00
DRV-01, DRV-02
DRV-03
DRV-04
DRV-005 ~ 07
DRV-08 ~ 10
DRV-11
DRV-12
FU1-00
FU1-03
FU1-05 ~ 06
FU1-07
FU1-08 ~ 11
FU1-12 ~ 13
FU1-20 ~ 21
FU1-22
FU1-23 ~ 25
FU1-26 ~ 28
FU1-29
FU1-30 ~ 37
FU1-38
FU1-39
FU1-50 ~ 53
FU1-54 ~ 55
FU1-56 ~ 58
FU1-59 ~ 60
FU2-01 ~ 06
FU2-07 ~ 08
FU2-10 ~ 16
FU2-19
FU2-20
FU2-21
FU2-22 ~ 25
FU2-26 ~ 27
FU2-30 ~ 37
FU2-39
FU2-40