5.3 Troubleshooting

Condition
1) Main circuit inspection:
2) Input signal inspection:
The Motor Does Not
3) Parameter setting inspection:
Rotate
4) Load inspection:
5) Other:
The Motor Rotates
Is the phase sequence of the output terminal U, V, W correct?
in Opposite
Is the starting signal (forward/reverse) connected correctly?
Directions
The Difference
Is the frequency reference signal correct? (Check the level of the input signal)
Between the
Is the following parameter setting is correct?
Rotating Speed and
Lower Limit Frequency (FU1-24), Upper Limit Frequency (FU1-25), Analog Frequency Gain (I/O-1~10)
the Reference is
Too Large
Is the input signal line influenced by external noise? (Use a shielded wire)
Is the acceleration/deceleration time is set too short a period of time?
The Inverter Does
Not Accelerate or
Is the load too large?
Decelerate
Is the Torque Boost (FU1-27, 28) value is too high that the current limit function and the stall prevention
Smoothly
function do not operate?
The Motor Current
Is the load too large?
is Too High
Is the Torque Boost Value (manual) too high?
Is the Upper Limit Frequency (FU1-25) value correct?
The Rotating Speed
Is the load too large?
Does Not Increase
Is the Torque Boost (FU1-27, 28) value too high that the stall prevention function (FU1-59, 60) does not
operate?
1) Load inspection:
The Rotating Speed
2) Input signal inspection:
Oscillates When the
Inverter is
Operating.
3) Other:
All manuals and user guides at all-guides.com
Is the input (line) voltage normal? (Is the LED in the inverter is lit?)
Is the motor connected correctly?
Check the operating signal input to the inverter.
Check the forward and the reverse signal input simultaneously to the inverter?
Check the command frequency signal input to the inverter.
Is the reverse prevention (FU1-03) function set?
Is the operation mode (FU1-01) set correctly?
Is the command frequency set to 0?
Is the load too large or is the motor jammed? (Mechanical brake)
Is the alarm displayed on the keypad or is the alarm LED lit? (STOP LED blinks)
Is the load oscillating?
Is the frequency reference signal oscillating?
Is the wiring too long when the inverter is using V/F control? (over 500m)
Chapter 5 - Troubleshooting & Maintenance