8. Appliance description

8.1
Standard delivery
The following are delivered with the appliance:
◦ Wall mounting bracket (incl. fixing screw and nut)
8.2 Special accessories
◦ IR Dimmer 3600 S Schuko
◦ IR Dimmer 3601
◦ IR Funk Dimmer 2000
◦ IR Funk W
◦ IR Funk S
◦ IR Funk Multi BiDi
◦ IR Strebenklemme (brace clamping bracket)

9. Installation

9.1
Installation conditions and
preparations
CAUTION Injury
!
Install the appliance out of the reach of children.
◦ Never install this appliance on or below combustible
materials.
◦ Never install the appliance directly below a socket.
◦ Install the appliance on the wall or ceiling.
◦ Observe the specified minimum clearances (see
chapter "Specification / Dimensions"). This appli-
ance gives off radiated heat. Therefore ensure that
there are no objects between the appliance and the
person or objects to be heated, such as furniture, for
example.
◦ Wood ceilings may become hot even if the minimum
clearances are observed. Dark spots or fine shrink-
age cracks on wooden ceilings may therefore occur.
9.2 Power supply
WARNING Electrocution
Carry out all electrical connection and installation
work in accordance with relevant regulations.
» Only connect the appliance to a correctly installed
mains socket.
We recommend a dedicated fuse for this appliance (see
chapter "Specification / Data table"). From 3600 W up-
wards, only ever connect one appliance per fuse.
Note
Observe the type plate. The specified voltage must
match the mains voltage.
WARNING Electrocution
The appliance must be able to be separated from
the power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
Equip the supplying power circuit of the appliance
with an RCD (nominal earth leakage current ≤ 30 mA).
Installation – for qualified contractors
10. Installation
10.1 Appliance installation
Note
Check in chapter "Specification / Data table" wheth-
er you are able to install the appliance vertically or
horizontally.
» Secure the mounting bracket on the wall or ceiling
using suitable fixing materials.
» Secure the appliance to the mounting bracket using
the screw and nut provided.
» Route the power cable from the appliance either to-
wards the back, top or bottom.
10.2 Adjusting the tilting angle
The tilting angle can be adjusted over a range of 100°.
We recommend a setting of 45°.
CAUTION Burns
If the appliance is already in use, let it cool down
before adjusting the tilting angle.
» Undo both screws on the pivot hinge.
» Set an appropriate tilting angle.
» Retighten the two screws again.
Material losses
!
Ensure that the appliance does not come into con-
tact with the power cable.
10.3 Dismantling
Pull the mains plug out of the socket.
CAUTION Burns
First allow the appliance to cool down before trans-
porting or storing it.
Remove the appliance from the wall mounting bracket.

11. Handover

Explain the functions of the appliance to the user. Draw
special attention to the safety instructions. Hand over the
operating and installation instructions to the user.

12. Troubleshooting

Only use an original spare part from us if you are replacing
the power cable.