Keep dry
Serial number
SN
The CE labelling certifies that the product
complies with the essential requirements of
0483
Directive 93/42/EEC on medical products.
Advice on use
• In order to ensure comparable values, always measure your
blood pressure at the same time of day.
• Before every measurement, relax for about five minutes.
• If you want to perform several measurements on the same
person, wait five minutes between each measurement.
• Do not take a measurement within 30 minutes after eating,
drinking, smoking or exercising.
• Repeat the measurement if you are unsure of the measured
value.
• The measurements taken by you are for your information
only – they are not a substitute for a medical examination!
Discuss the measurements with your doctor, and never
base any medical decisions on them (e.g. medicines and
their administration)!
• Do not use the blood pressure monitor on newborns, preg­
nant women or patients with preeclampsia.
• Cardiovascular diseases may lead to incorrect measurements
or have a detrimental effect on measurement accuracy. The
All manuals and user guides at all-guides.com
• The blood pressure monitor must not be used in connection
• Only use the device on people who have the specified
• Please note that when inflating, the functions of the limb in
• During the blood pressure measurement, blood circulation
• Avoid any mechanical restriction, compression or bending
• Do not allow sustained pressure in the cuff or frequent
• Ensure that the cuff is not placed on an arm in which the
• Do not use the cuff on people who have undergone a mas­
• Do not place the cuff over wounds as this may cause further
• You can either use the blood pressure monitor with batteries
14
same also applies to very low blood pressure, diabetes, circu­
latory disorders and arrhythmias as well as chills or shaking.
with a high­frequency surgical unit.
upper arm measurement for the device.
question may be impaired.
must not be stopped for an unnecessarily long time. If the
device malfunctions, remove the cuff from the arm.
of the cuff line.
measurements. The resulting restriction of the blood flow
may cause injury.
arteries or veins are undergoing medical treatment, e.g. intra­
vascular access or therapy, or an arteriovenous (AV) shunt.
tectomy.
injury.
or with a mains part. Please note that data transfer and data
storage is only possible when your blood pressure monitor
is supplied with power. As soon as the batteries are empty
or the mains part is disconnected from the power supply,
the blood pressure monitor loses the date and time.