 For extraction mode, you must also create a feed
through of approx. Ø 130 mm in the base of the
unit.
 If the mains cable is fed through the unit, a feed
through also must be provided.
 Drill four mounting holes of Ø 4 mm through the
base of the unit. Screw in the appliance with the
screws including washers (3) under the wall unit
and tighten the nuts (4) through the housing.
 For extraction mode insert the connecting piece
with non-return valves (5) from above onto the air
outlet. Thereto a flexible extraction hose (not sup-
plied) with an inner diameter of Ø 120 mm must
be fitted and connected to the outside by an ex-
traction vent.
 For recirculation mode close the air outlet by put-
ting on the cover (6).
 Reinstall the aluminum grease filter.
Installing the activated carbon filter mat for recircula-
tion mode
 Remove the aluminum grease filter (see
ing the aluminum grease filter"
 Insert the previously fitted carbon filter mat parts
onto the grease filter and fix the mat parts each
with two metal struts (supplied with carbon filter
mat).
 Reinstall the aluminum grease filter with fixed
carbon filter mats.
"Clean-
).
20
Electrical connection
WARNING:
 The installation to the mains supply must conform
to the local standards and regulations.
 Improper connection may cause to an electric
shock!
 Do not modify the appliance plug. If the plug does
not fit properly to the outlet, let install a proper
outlet by an authorized specialist.
 The accessibility of the power plug must be en-
sured to disconnect the appliance from the power
supply in case of emergency.
 Ensure that your mains power corresponds with
the specifications of the appliance. The specifica-
tions are printed on the rating label.
 Connect the mains cable to a properly installed
and earthed wall outlet.
 If the plug after installation is not accessible, a
corresponding disconnect device must be availa-
ble to meet the relevant safety regulations.

Startup / Operation

The extractor hood is operated via two slide switch-
es. The lighting as well as the fan settings must be
switched on and off with the corresponding switches.
Power level
0 off
1 low
Lighting
0 lighting off
Settings
Power level 1:
Suitable for cooking on a low flame and for dishes
which produce no or little steam to circulate the air
around the kitchen.
Power level 2:
Suitable for normal cooking.
2 medium
3 high
1 lighting on