For exhaust mode:
Hereupon a flexible exhaust hose
(not delivered) with 150 mm inner diameter must be
attached.
 Hang up the hood body onto the bracket [05].
Check the safe, horizontal support and tighten two
screws ST4x30mm [09] through the hood body.
For exhaust mode:
Check the correct position of the
exhaust hose and connect it with the outlet opening.
 Put the shaft unit on and secure the lower shaft
with the bracket [03].
 Pull up the inner shaft and fix the shaft cover
sideways with the bracket [04] by screwing in the
screws ST3x10mm [10].
Installing the activated carbon filter for recirculation
mode
 Remove the aluminum grease filter (see
ing the aluminum grease filter
 Place the carbon filter onto the air intake of the
extraction duct. Make sure that the mounting pins
on the extraction duct engage the mounting slots
of the carbon filter. Turn the filter clockwise until it
clicks into place.
 Reinstall the aluminum grease filter.
Electrical connection
WARNING:
 The installation to the mains supply must conform
to the local standards and regulations.
 Improper connection may cause to an electric
shock!
 Do not modify the appliance plug. If the plug does
not fit properly to the outlet, let install a proper
outlet by an authorized specialist.
"Clean-
).
20
WARNING:
 The accessibility of the power plug must be en-
sured to disconnect the appliance from the power
supply in case of emergency.
 Ensure that your mains power corresponds with
the specifications of the appliance. The specifica-
tions are printed on the rating label.
 Connect the mains cable to a properly installed
and earthed wall outlet.
 If the plug after installation is not accessible, a
corresponding disconnect device must be availa-
ble to meet the relevant safety regulations.

Startup / Operation

The cooker hood is operated via push buttons:
Power level
off
low
Light
on / off
Settings
Power level: Suitable for cooking on a low flame
and for dishes which produce no or little steam to
circulate the air around the kitchen.
Power level: Suitable for normal cooking.
Power level: Suitable if large quantities of smoke
and steam need to be extracted or filtered (e.g. when
frying).
NOTE:
With very strong vapor emission, the fan should con-
tinue running after cooking for a few minutes.
medium
high