Compressor - maintenance
With the following table you can see the service-clearance of the compressor. The service – clearances are given
in operating hours.
Use only synthetic oil for the compressor (Gimaex-Schmitz item-no. #7971), the guarantee becomes void when
using an other oil.
Attention!
When operating in soiled surroundings the oil change should take place more frequent.
Belt tension
Change belt
Check oil level
Oil change
Change oil filter
Clean air filter
Change air filter
Inspect oil leakage
Check function of safety valve
Check condition of the hoses
Check strainer in the inclined position valve
All manuals and user guides at all-guides.com
- 18 -
regular control
(increase the tension when necessary, by moving the
)
base plate
when necessary
(Lose screwing of the base plate, change belt, tense belt
by moving the base plate.)
after every operation
(Oil level approx. center inspection glass)
after 100 operating hours, resp. at least 1 x
Annual
(fill new oil up to top edge inspection glass)
after 100 operating hours, resp. at least 1 x
annual
after 100 operating hours
1 x annual
after every operation, resp. regular control
regular control
regular control
after every operation, resp. regular control
Gimaex-Schmitz Fire and Rescue GmbH
Postfach 1136, 57225 Wilnsdorf
Essener Straße 8, 57234 Wilnsdorf
Telefon +49 (0) 27 39 / 80 9-0
Telefax +49 (0) 27 39 / 80 9-99
www.gimaex-schmitz.com
info@gimaex-schmitz.com
!

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Schmitz ONE SEVEN OS 1200 SU

Inhaltsverzeichnis