Dismantling the
inverter module
Fig.1
-
-
-
Fig.2
-
-
-
(1)
(1)
Loosen screws on the inverter module
Remove side panels
Loosen screws (1) and (2) first
Subsequently loosen screws (3)
Unplug 12-pole Molex plug
Pre-clean heat sink by means of alcoholic solvent or contact spray
Remove contaminations and unevenness on the heat sink by means of a fine
abrasive paper (e.g. P 500 or finer)
Clean heat sink with alcoholic solvent or contact spray and a non-fraying cloth.
(3)
(3)
-
Unplug 12-pole Molex plug (4) at X8
on FMW 22 print
-
Loosen inverter module by carefully
moving it away from the heat sink and
remove it