Herunterladen Inhalt Inhalt Diese Seite drucken

General Technical Specifications; Technical Specifications; Power Consumption Of The System Components - Siemens SIMATIC IPC847E Produktinformation

Einfache stromversorgung (850 w)
Vorschau ausblenden Andere Handbücher für SIMATIC IPC847E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

General technical specifications

Supply voltage (U
)
N
Input current
Power consumption with maximum
configuration and 520 W secondary
Power loss, heat emission

Technical specifications

Note
The maximum permissible ambient temperature range for operating the device is 0 - 50° C.
Read the notes in the operating instructions regarding possible restrictions of certain device configurations.
Voltage
+12 V
–12 V
+5 V
+3.3 V
+5 V
aux
The total output of the +5 V and +3.3 V voltage must be ≤ 200 W.
1
The total output of all voltages amounts to a max. of 850 W and depends on the temperature of the intake air inside the
device:
Up to 40° C: 100% of 850 W, (derating 1% / K)
As of 50° C: 90% of 850 W, (derating 2% / K)
As of 60° C: 70% of 850 W, (derating 1% / K)
As of 70° C: no operation permitted

Power consumption of the system components

Performance of the expansion cards
Total power consumption, permissible
SIMATIC IPC847E - Single Power Supply (850 W)
A5E51125364-AA, 06/2021
100 to 240 V AC (-10%; +10%)
Continuous current 12 - 6 A at 100 - 240 V~ nominal voltage
With startup 25° C (cold restart): 115 - 230 V ≤ 180 A
Dimensioning of the fuses in the higher-level plant circuits
A fuse that is designed for a typical tripping current of 15 A is integrated in the power
supply unit of the IPC. The pulse currents during startup are also taken into account by
the "time lag" type. In the case of a fault, this fuse ensures the correct disconnection
of the device from the power supply system. It is recommended that a fuse of at least
15 A, plus the power demand of the other devices that are also supplied via this
circuit, be used for protection of the higher-level power supply circuit. The tripping
characteristic of the higher-level protection must take into account the starting
currents of both the IPC and the other devices.
≤ 600 W with 87% efficiency
600 W = 600 J/s = 0.57 BTU/s
Maximum current
70 A
0.3 A
35 A
1
20 A
1
3 A
The maximum power loss of the expansion cards amounts to 80 W.
It may be increased by 265 W if the power is drawn from an actively cooled
expansion card (e.g.: high-end graphics card) that emits its waste heat directly
into the ambient air and not into the interior of the device. The requirements of
the expansion card for the temperature of the intake air (inside the device) must
be observed.
The total output of all voltages amounts to a max. of 255 W.
It may be increased by 265 W if the power is drawn from an actively cooled
expansion card (e.g.: high-end graphics card) that emits its waste heat directly
into the ambient air and not into the interior of the device. The requirements of
the expansion card for the temperature of the intake air (inside the device) must
be observed.
Voltage stability
± 5%
± 10%
± 5%
± 5%
+5%