Herunterladen Diese Seite drucken

De Dietrich DHD498XE1 Gebrauchs- Und Installationsanweisung Seite 25

Wand-dekorhauben

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes
or at least every 4 months. The alarm signal will only light up when the extractor motor is
switched on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or
at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power
supply.
• Restore the connection by pressing and holding T1.
• Release the button. All five LEDs are turned on.
• Wit hin 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
- LED flashes twice - Activated charcoal filter saturation alarm ENABLED.
- LED flashes once - Activated charcoal filter saturation alarm DI SABL ED.
Alar m signal r eset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to
flash.
Replacing the Filter
• Remove the metal grease filters
• Remove the saturated activated carbon filters as shown (A).
• Fit the new filters (B).
• Replace the metal grease filters.
20 W halogen light .
• Remove the light cover by unfastening the screws that hold it.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the light cover.
EN
All manuals and user guides at all-guides.com
2
25
5

Werbung

loading