2.
Installation instructions
Installation, electrical connection, and first start-up must be carried out by a qualified installer
who is registered by the appropriate electricity supply company, under observance of these
installation instructions.
2.1
Unit construction
1
Natural stone slab
2
Wall mountings
3
Heating cable, embedded
4
Mains connection cable
5
Spacer bolts
6
Wall mounting securing screw
7
Hexagonal screw
A channel system is cut into the back of the natural stone slab, into which a heating conductor
with two automatic-reset safety thermal cut-out is inserted.
To cover this over, the channel system is finally filled with marble bonding cement.
2.2
Technical Data
Type
Stone type
Rated power
Rated voltage
Dimensions
H x W x D
Weight
Mains connection
Protection class
Protection mode
Test certificates
NSH 35
NSH 65
W
350
mm
400 x 600 x 30
400 x 1000 x 30 500 x 1000 x 30 600 x 1000 x 30 600 x 1250 x 30
kg
21
Connection lead approx. 100 cm; permanent connection; 2 x 0.75 mm²
NSH 85
(VA / JA / VO / MC / PR / SA / PA / LA / ...)
650
850
1/N ~ 230 V 50 Hz
35
44
II
IP 25, water jet protection
VDE, EMV, GS, CCA, CE
For the Fitter
NSH 115
NSH 145
1150
1450
52
62
9