5.8.1 Installing the control

the installation of the pump control. The connecting cable of the pump is 3.50 m long. The
installation site of the control has to be selected accordingly. The control has to be installed
in such a way that the cable entries face downward.
!
The control must be installed in such a way that the blue pneumatic hose for the level
control can be laid rising steadily from the lifting unit to the connection at the switch box.
This is the only way to ensure proper functionality of the automatic control.
i
With the electrical connection of the control, a disconnecting device should exist locally.
82
Kompaktboy Double
1.
Transfer the hole pattern onto the wall.
2.
Drill 4 holes, suck away and drive in dowels.
3.
Open the control cover – while doing so, check to
see that no cable connections are loosened.
4.
Using 4 screws, tighten the control.
5.
Put on the control cover and screw down –
while doing so, check to see that no cables are
jammed.