Herunterladen Inhalt Inhalt Diese Seite drucken

Zehnder Pumpen Kompaktboy Doppel Gebrauchsanleitung Seite 75

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

described in the following. Mounting of the right valve is carried out analogously.
Kompaktboy Double
1.
Lay the supplied seal ring (O-Ring DN 100) into
the groove of the pressure outlet of the collecting
tank.
2.
Insert the threaded bolt (M16x60) into hole 1
3.
range the holes/threaded hole congruently.
4.
Screw the nut (M16) on the threaded bolt 1.
5.
Screw in the 3 screws M16x40 and
tighten the 4 screw connections equally cross-
wise.
6.
Put the flange seal DN 100 on the connection
flange of the shut-off valve.
7.
Put on the Y-pipe. While doing so, arrange the
holes/threaded holes congruently.
8.
Create screw connections with 4 screws
M16x100 and
4 nuts M 16 between the shut-off valve and
adapter flange and equally tighten crosswise.
en English
-
75

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kompaktboy 1.1Kompaktboy 1.5Kompaktboy 3.0

Inhaltsverzeichnis