Charging process
DELETING AN RFID CARD FROM THE LOCAL LIST
#
Action to be carried out
Swipe the MASTER key across the RFID reader to access
1
Swipe the MASTER key across the RFID reader until you reach
2
3
Swipe the RFID card that you want to delete across the reader
To quit the RIFD card storage menu, swipe the MASTER key across
4
the RFID reader until the standard message appears
B. ADDING A BATCH OF RFID CARDS TO THE LOCAL LIST.
If numerous RFID cards need to be added to the local list of the charging station, or if this task must be carried out on a number of
stations, it can be speeded up by creating a .csv file to be saved on the microSD inside the station. Proceed as follows:
#
1
2
Open the front door and remove the microSD on the electronic board (slot on the upper left side).
3
4
5
6
After creating the structure and saving the file in the microSD, put the microSD back in the electronic board.
7
If the procedure has been completed without errors, the station will import the file and the data it contains.
8
The message CONFIGURATION COMPLETED will appear on the display. At the end of the import procedure,
9
Check the import has been completed correctly by swiping one of the cards from the newly imported local list.
To enable a recharging session:
#
Action to be carried out
1
Check the display to make sure there are no charging station errors
2
Swipe an RFID card across the reader, near the graphic symbol
If the card is recognised (i.e. it is in the local list), the station will
3
release both type 2 socket-outlets and the client can choose the one
Insert the recharging plug in the required socket-outlet of the station,
4
Once the connection has been made, the station checks the CP and
5
PP signals to make sure the session can be started
Once the CP and PP signals have been checked, the recharging
6
station will mechanically block the plug in the socket-outlet.
The recharging session begins
7.55.4.515.2 - Installation and Operation Manual
Installation and Operation Manual
the storage menu
the required section
Action to be carried out
Disconnect the power supply to the charging station.
Insert the microSD in the computer (it might be necessary to use adapters).
Create a .csv file with the name RFID.csv in the main directory.
In this file, create the data structure following this pattern:
Power the charging station again.
the file will be renamed RFID_old.csv on the microSD.
he/she prefers
and in the vehicle
RGB LED status
Words on the display
Fixed green
SWIPE THE CARDS
Fixed green
SWIPE THE CARDS
Fixed green
SWIPE THE CARD
Fixed green
UID1;
UID2;
UID3.
RGB LED status
Words on the display
SWIPE THE CARD
Fixed green
Fixed green
CHARGING ENABLED
Flashing green
CONNECT THE CABLE
CHARGING ENABLED
Flashing green
CONNECT THE CABLE
Fixed green
RECHARGE IN PROGRESS
Ts=0000 Tc=0000
Flashing blue
RECHARGE IN PROGRESS
kW=0000 kWh=0000
Gewiss
*SAVING*
*DELETION*
RECOGNITION
*PLEASE WAIT*
TO RECHARGE
TO RECHARGE
CARD ENABLED
*PLEASE WAIT*
PLEASE WAIT