Herunterladen Inhalt Inhalt Diese Seite drucken

Device Installation (Column Version); Mechanical Installation - Gewiss JOINON I-ON Serie Installations- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 173
Device installation and connection

7.2. Device installation (column version)

7.2.1. Mechanical installation

1.
Prepare the assembly area with four tie-rods embedded in the cement (if you are using the fixing plate - accessory GWJ8021 -
embed it in the ground). The figure below shows the position of the anchorage point on the device. There are two options for
fixing the device in the ground:
NB: the fixing points highlighted in blue allow this device to be installed in place of the old Parking+ devices.
2.
These charging stations have a front access door with key opening to facilitate installation and connections. Open the door
using the key supplied. The safety key can only be removed when the door is fully closed.
3.
Couple the fixing base (already fixed to the ground) with the charging station.
4.
Fix the column on the base, tightening the nuts on the pins indicated in the figure. The maximum tightening torque is 20 Nm.
NB: it's important to complete the earth connection of the base. To do this, insert the eyelet of the earth cable on a fixing pin, then
tighten it with the relative nut as shown in the figure.
5.
Check that the device is correctly fixed in place.
6.
Remove the protective film from the front panel.
7.55.4.515.2 - Installation and Operation Manual
Installation and Operation Manual
196 mm
150 mm
Ø14 mm
Ø14 mm
Gewiss
IT
EN
FR
ES
DE
RO
HU
NL
59

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Joinon i-on wall serie

Inhaltsverzeichnis