Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning; Mounting The Extraction Arm - Abicor Binzel xFUME FLEX Betriebsanleitung

Niedrigvakuum-rauchgas-absauggerät
Vorschau ausblenden Andere Handbücher für xFUME FLEX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

xFUME FLEX

6 Commissioning

Risk of injury due to fire
Improper use or connection can result in fire. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate is suitable for the connection voltage.
► Do not use the device to extract welding fumes that result from welding oil-wetted parts.
► Do not use the device to extract flammable substances and liquids.
► Do not use the device in areas subject to dust or gas explosion hazards.

6.1 Mounting the extraction arm

NOTICE
Material damage due to excessive rotation
The extraction arm may become damaged if it is rotated past its limit stop.
► Do not rotate the extraction arm past the limit stop (max. 350°).
Fig. 3
A Extraction hose
B Extraction rod
WARNING
Attaching the extraction hose
A
B
C
D
C Connecting tube
D Extraction hood
Push the rubber sleeve over the connecting piece
1
and unfold outward.
Lay the gripping clamp over the rubber sleeve.
2
Mount the extraction rod on the mounting tube
3
with two M8 hexagon bolts, washers and
hexagon nuts.
Connect the electric cable that extends from the
4
extraction rod to the device (plug-in connection).
Connect the corresponding cable colors.
The black cables are labeled with the numbers 1
and 2. Connect the cables with the number 1 and
connect the cables with the number 2.
6 Commissioning
EN - 11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis