Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel xFUME FLEX Betriebsanleitung Seite 32

Niedrigvakuum-rauchgas-absauggerät
Vorschau ausblenden Andere Handbücher für xFUME FLEX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Commissioning
EN - 12
Pull the extraction hose over the handle in the
5
direction shown.
Fold the rubber sleeve on the device over the
6
extraction hose and fix with the gripping clamp.
Place the connecting tube in position and pull the
7
rubber sleeve over the connecting tube until it
covers the metal flange. The rubber sleeve must be
on the plastic tube so that it subsequently creates
a seal with the metal flange.
Fold the rubber sleeve down halfway, so that the
8
metal flange is protruding at the top.
Feed the extraction hood's electric cable through
9
the connecting tube from the bottom.
Insert the extraction hood into the connecting tube
10
and rotate it once to secure it in place.
Place the clamp over the metal flange and attach
11
it loosely.
Slide the connector over the profile tube until the
12
screw holes are aligned and then secure the
connector to the profile tube using the screw.
The electric cable must be protruding out of the
metal flange.
xFUME FLEX

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis