Herunterladen Inhalt Inhalt Diese Seite drucken

Pin Assignment; About This Documentation; Notes On Safety; Intended Use - Emerson AVENTICS PE5 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für AVENTICS PE5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Internally stored parame-
ters

2 Pin Assignment

Fig. 24: Pin assignment, 4-pin
Pin
Assignment
1
24 V power supply (+)
2
Digital switch output 2 (PNP/NPN/push-pull, switchable)
3
0 V power supply (-)
4
Digital switch output 1 (PNP/NPN/push-pull, switchable)
Pin
Assignment
1
24 V power supply (+)
2
Analog output (4 to 20 mA/0 to 10 V)
3
0 V power supply (-)
4
Digital switch output 1 (PNP/NPN/push-pull, switchable)
Pin
Assignment
1
24 V power supply (+)
2
Digital switch output 2 (PNP/NPN/push-pull, switchable)
3
0 V power supply (-)
4
IO-Link/digital switch output 1 (PNP)
Fig. 25: Pin assignment, 5-pin
Pin
Assignment
1
24 V power supply (+)
2
Digital switch output 2 (PNP/NPN/push-pull, switchable)
3
0 V power supply (-)
4
Digital switch output 1 (PNP/NPN/push-pull)
in leakage mode: digital switch input PNP
5
Analog output (4 to 20 mA/0 to 10 V)

3 About This Documentation

This documentation is valid for PE5 series pressure sensors.
This documentation is intended for installers, operators, and service technicians.
Only commission the product once you have obtained the system documenta-
tion and understood and complied with its contents.

4 Notes on Safety

The product has been manufactured according to the accepted rules of current
technology. Even so, there is danger of injury and damage to equipment if the
following chapter and safety instructions of this documentation are not followed.
1. Read these instructions completely before working with the product.
2. Keep this documentation in a location where it is accessible to all users at all
times.
3. Always include the documentation when you pass the product on to third par-
ties.
AVENTICS™ PE5 | R412010843-BAL-001-AG | English
Adjustable parameters
4
3
1
2
2
1
5
3
4
Output value

4.1 Intended use

The pressure sensor is a pneumatic device for the monitoring of pressure values.
It is intended for application in a machine or system. It may be operated only in
the installed state.
Use within the limits listed in the technical data.
u
The product is intended for professional use only.
Improper use includes installing the pressure sensor in hydraulic systems or ap-
plying aggressive or flammable gases, or liquids, to it.
No liability is assumed for any damages resulting from improper use. The user
alone bears the risks of improper use of the product.

4.2 Personnel qualifications

P
1 UB
2 OUT2
3 0V
4 OUT1
The work described in this documentation requires basic mechanical and pneu-
matic knowledge, as well as knowledge of the appropriate technical terms. In or-
der to ensure safe use, these activities may therefore only be carried out by quali-
fied technical personnel or an instructed person under the direction and supervi-
sion of qualified personnel.
Qualified personnel are those who can recognize possible hazards and institute
the appropriate safety measures, due to their professional training, knowledge,
P
1 UB
2 analog
and experience, as well as their understanding of the relevant regulations per-
3 0V
4 OUT1
taining to the work to be done. Qualified personnel must observe the rules rele-
vant to the subject area.

4.3 General safety instructions

• Observe the regulations for accident prevention and environmental protec-
tion.
P
1 UB
2 OUT2
3 0V
• Observe the safety instructions and regulations of the country in which the
4 C/OUT1
product is used or operated.
• Only use AVENTICS products that are in perfect working order.
• Follow all the instructions on the product.
• Use only accessories and spare parts approved by the manufacturer.
• Comply with the technical data and ambient conditions listed in the product
documentation.
• Never modify the product on your own authority.
• You may only commission the product if you have determined that the end
product (such as a machine or system) in which the AVENTICS products are in-
stalled meets the country-specific provisions, safety regulations, and stan-
dards for the specific application.
1 UB
P
2 OUT2
3 0V
4 OUT1 / IN
5 analog

4.4 Safety instructions related to the product and technology

Improperly installed compressed air lines!
Danger of injury!
Lay the compressed air lines so that no one can trip over them.
u
Dangerous system operating states if the pressure sensor is disconnected
from the voltage source during operation!
Danger of injury and system damage from uncontrolled system operating
states.
Do not disconnect the pressure sensor from the voltage source during op-
u
eration.

4.5 General instructions on equipment and product damage

Mechanical loads!
Damage to the device!
1. Make sure that you never expose the device to mechanical loads or mount
it with mechanical stress.
2. Avoid mechanical stress when connecting the pneumatic tubing and the
electrical connection.
3. Make sure that the device is not damaged by falling parts or incorrect tool
usage.
CAUTION
CAUTION
NOTICE
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis