Intended Use; Technical Data; Maintenance And Cleaning - EINHELL IH3000 Bedienungsanleitung

Industrieheizer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung_IH_3000_SPK7:_
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout (Fig. 1)
1 Heat output switch
2 Thermostat control
3 Heater
4 Air outlet grille
5 Fan

3. Intended use

The equipment can be used in enclosed rooms in a
free standing position for room heating. Keep a
minimum distance of 1 m between the front of the
housing and walls, combustible materials (furniture,
curtains, etc.) and 30 cm from all other housing
surface areas. The equipment may only be used
completely mounted and standing vertically on a
stable surface. It is prohibited to operate the
equipment on an instable surface (e.g. on a bed).
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data:

Rated voltage:
Output:
3000 W (1500 W / 3000 W)
Thermostat control:
Protection type:
Appliance dimensions, approx.:
07.05.2008
10:02 Uhr
Seite 7
5. Starting up
Important. Before using the equipment for the first
time, check that the voltage supply is the same as
the voltage details set out on the rating plate.
Read the safety regulations in section 1.
After the hot equipment has been switched off (by
turning the heat output switch to "0") the fan may
continue to run for a while to cool the equipment. If
the fan continues to run for more than 10 minutes, it
cannot cut out automatically as a result of the high
room temperature. In this case the mains plug must
be pulled.
5.1 Heat output switches (Fig. 1):
Off setting (0)
Fan setting (
Low heat output
Maximum heat output
5.2 Thermostat control (Fig. 1 / Item 2):
Note:
The fan will start as soon as the equipment is
switched on.
The equipment will only heat up when the room
temperature falls below the temperature set on the
thermostat and the heat output switch is on.
Switch on the required heating output. Turn the
control to "max" until the required room temperature
has been reached. Then turn down the control until
you hear a clear click. The thermostat will switch the
heating element on and off automatically.
5.3 Overheating guard
In case of excessive heating, the heating function
shuts down automatically. The fan will restart.
If this occurs, turn off the equipment, disconnect the
mains plug and wait a few minutes for the equipment
to cool. After eliminating the cause (e.g. a covered
air grille), the equipment can be switched on again.
If the overheating guard triggers repeatedly, please
contact your customer service center (in Germany
230 V ~ 50 Hz
ISC GmbH).
Infinitely adjustable

6. Maintenance and cleaning

IP24
29,5 x 25 x 43 cm
Before carrying out any cleaning and maintenance
work the appliance must be turned off,
disconnected from the power supply and cooled
down.