Herunterladen Inhalt Inhalt Diese Seite drucken

Victron energy SmartSolar MPPT 150/70-Tr VE.Can Anleitung Seite 16

Vorschau ausblenden Andere Handbücher für SmartSolar MPPT 150/70-Tr VE.Can:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 77
3.9 Automatic equalization
Automatic equalization is default set to 'OFF'. With the Victron Connect app
(see sect 1.12) this setting can be configured with a number between 1
(every day) and 250 (once every 250 days).
When automatic equalization is active, the absorption charge will be followed
by a voltage limited constant current period. The current is limited to 8% or
25% of the bulk current (see table in sect. 3.5). The bulk current is the rated
charger current unless a lower maximum current setting has been chosen.
When using a setting with 8% current limit, automatic equalization ends
when the voltage limit has been reached, or after 1 hour, whichever comes
first.
Other settings: automatic equalization ends after 4 hours.
When automatic equalization is not completely finished within one day, it will
not resume the next day, the next equalization session will take place as
determined by the day interval.
14

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis