Alarm
Cause
Gp.3
This alarm is triggered when the brew
sensor
group 3 temperature sensor is out of
short circuited
range
High
This alarm is triggered when the
temperature
temperature of brew group 3 has gone
Gp.3
above 120 °C
Gp.1
This alarm is triggered when group 1 is
volume
brewing and the electronic control does
meter failure
not receive signals from the flowmeter
corresponding to the same group
Gp.2
This alarm is triggered when group 2 is
brewing and the electronic control does
volume
not receive signals from the flowmeter
meter
corresponding to the same group
failure
Gp.3
This alarm is triggered when group 3 is
volume
brewing and the electronic control does
meter failure
not receive signals from the flowmeter
corresponding to the same group
Effect
Brew group 3 heating blocked;
tap DEL on the display to cancel
the alarm
Brew group 3 heating blocked;
tap DEL on the display to cancel
the alarm
Brewing must be stopped
manually by pressing the same
button used for the brewing
in progress
Brewing must be stopped
manually by pressing the same
button used for the brewing
in progress
Brewing must be stopped
manually by pressing the same
button used for the brewing
in progress