6. STORAGE
To put into storage / Overwintering:
1. To preserve the battery, it should be
removed (see 3. INITIAL OPERATION ).
The programmes remain stored. If the battery is
inserted again in spring, only the time of day and
the weekday must be newly entered.
2. Store controller and valve unit in a dry place
where they are protected from frost.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to
normal household waste. It must be disposed
of in line with local environmental regulations.
7. TROUBLESHOOTING
Problem
No display appears
Manual watering is
not possible using the
Man. button
Watering program is
not carried out
(no watering)
20
1874-20.960.09.indb 20
IMPORTANT!
v Dispose of the product through or via your
municipal recycling collection centre.
Disposing of flat batteries:
v Please return flat batteries to a GARDENA dealer
or dispose of them properly at your nearest
recycling centre.
Only dispose of batteries when they are flat.
Possible Cause
Battery inserted incorrectly.
Flat battery.
Temperature on the display is
higher than 60 °C.
Battery flat (frame is flashing).
Manual watering period is set
to
.
0:00
Tap turned off.
Watering program has not
been entered completely.
Programs deactivated
(Prog.
).
OFF
Program entry / modification
during or just before the start
pulse.
Valve was opened manually
previously.
Tap turned off.
Soil moisture sensor reads wet
(wet).
Battery flat (frame is flashing).
Controller is not connected
(no display with V1 / V2).
Remedy
v Check polarity markings
match (+ / –).
v Insert new alkaline battery.
v Display appears after
temperature has dropped.
v Insert new alkaline battery.
v Set manual watering period to
a figure greater than
0:00
(see 4. PROGRAMMING).
v Turn tap on.
v Read off watering program
and modify if necessary.
v Activate program
(Prog.
).
ON
v Make program entry /
modification outside the
programmed start times.
v Avoid possible program
overlaps.
v Turn tap on.
v If sensor reads dry, check
the settings / location of the
soil moisture sensor.
v Insert new alkaline battery.
v Mount controller on housing.